Product
  • Thermal shock test chamber for 2 Temp. zone structure
  • Thermal shock test chamber for 2 Temp. zone structure
Thermal shock test chamber for 2 Temp. zone structure

Utility model patent: Energy saving refrigeration system ZL202221162918.2 for cold and hot shock test chamber

Software Copyright: Energy saving Temperature Thermal Shock Test Measurement and Control System (Software Patent No. 0922788)

CE Safety Certification Number: AT58250SC01000086

Consult Now

+86-755-26478771

Equipment Introduction
1.Device introduction:

Thermal shock test chamber is used to test all kinds of raw materials or finished products under the continuous instantaneous conversion of extreme high temperature and extreme low temperature. To evaluate the reliability of physical, chemical and electrical properties of raw materials or finished products.


2. Device features:

2.1. The equipment production and testing are strictly carried out in accordance with national standards, with key core parameters such as temperature deviation, fluctuation, uniformity, test chamber air reset time, and sample surface reset time meeting the relevant requirements of GB2423 (IEC60068), which can completely replace similar products in Europe, America, and Japan.


2.2. More than 2400 hours of single fault free continuous operation; The operating life of the machine is more than 100000 hours, the safety performance has passed the EU CE safety inspection certification.


3. Device specification:

Model No.

TS-II-50A/B

TS-II-100A/B

TS-II-200A/B

Internal volume

50L

100L

200L

Internal dimension

W40×H32×D40cm

W50×H40×D50cm

W78×H40×D65cm

External dimension

W128×H198×D180cm

W135×H204×D185cm  

W162×H206×D220cm

Weight(Kg)

1000/1200

1100/1300

1200/1400

Device structure

2 temp. zone structure, it is divided into two parts: cold zone and hot zone, and can be automatically switched by lifting the pneumatic program of the hanging basket.

Shock test mode

Low temperature → high temperature→ low temperature or high temperature→

low temperature →high temperature; so reciprocating cycle

Performance parameter

Temp. range

Temperature shock range

A type(-40~180°C)(-60℃~180℃)

 B type(-65~200°C)

High temperature storage range

60℃~200℃

60℃~220℃

Low temperature storage range

-60℃~-10℃

-75℃~-10℃

Shift time

≤10S

Recovery time

≤3Min

Sample surface recovery time

 ≤6Min(Subject to IC surface)

Temperature uniformity

≤2.0℃

Temperature deviation

  ±2.0℃

image.png
Related Recommendations
Tel: 86-755-26478771
Email: jon.zhang@sztops.cn
Web site: http://www.sztops.cn
Address: Building A, No. 222 Xiangshan Avenue, Luotian Community, Yanluo Street, Bao'an District, Shenzhen
Copyright © 2024 Shenzhen Dingzhun Electronics Co., Ltd. All rights reserved. Powered by EyouCms 粤ICP备15102210号